Otis 211 dlf fault. It was first made in 1987.
- Otis 211 dlf fault Both gates are made up. Cleared fault and car ran all day no issues. I have verified upper limits and magnets on tape. he wants to replace the main 211 board, but i would like to here some of your responses first. problem goes away for 5 months, and Mar 18, 2014 · Sounds like you are losing the feed to the DL valve. It is so intermittent we cannot nail down the actual cause. Oct 25, 2017 · Hey guys,Got an Otis 211 hydro that is displaying DTC on the board in the controller. Display scrolls run 187, 365. News Feed; Facebook; Oct 9, 2013 · Re: otis 211 dlfb fault - 10/09/13 02:51 AM I don't know if its software related but you might have a low-pressure switch acting up. problem goes away for 5 months, and Report Fault Online. 5''below the flooralso had to Oct 9, 2013 · Re: otis 211 dlfb fault - 10/09/13 02:51 AM I don't know if its software related but you might have a low-pressure switch acting up. so instead of Feb 6, 2010 · Otis 211 DZ fault, magnet problem (2002-05-21) otis elevonic bounces in high speed encoder amplifier brd and both power amps ok what do you think (2002-05-20) Hydrolic Pump motor didn't shut off (2002-05-20) schematics (2002-05-19) shephard residential (2002-05-16) Need Otis print-10NIBL (2002-05-15) Help for PLC Logic (2002-05-13) Mar 21, 2013 · Have a newer Otis 211 5 stop with 1 short floor. Hey there, I’ve got an Otis 211 that every time there is a power outage in the area, the elevator will fault out with a 2EFO fault and the car will park at the second landing with the doors open. The Otis HydroFit model elevator uses a different controller now, which does not have an official name. Your employer is not your slave master. I saw the 2 dto fault and I think it means "door timer open" fault or something. Feb 12, 2017 · #19554 - 02/12/17 04:03 AM Re: OTIS 211 BYOP FAULT [Re: micmerci] Joined: Sep 2016 Posts: 14 Nelson stranger Nelson stranger Joined: Sep 2016 Posts: 14 Portugal: May 25, 2013 · Two stop Otis 211 with no leaks but will shut down after sitting idle for 5 mins with a valve fault on the on board diagnostic tool. Oct 7, 2024 · No power on doors DTC Fault think doors need reset have blue tool but can't connect initially connects but then goes to all Z's car runs on inspect but the when goes back to normal still no power on doors DTC comes up and nudging buzzer,can't reset from controller think it has to be top of Oct 1, 2011 · On that last post, if you add oil additive for a tight packing it will change the viscosity of the oil. every once in a while, the screen will display the floor number and iii, then will go back to the floor number and IDL, or NOR which is usual. If you don't find anything replace the board. Unit is set to park at the lobby floor. Mar 5, 2015 · Hi I have a 3 stop hydro with an Otis 211 controller. S. Any sugge Supplier Code of Conduct. 3NAV. No one uses elevator at night in this building other than the cleaner. Saiba como os colaboradores da @OtisElevatorCo se desenvolvem de maneira inspiradora. 5 : 15 . There is no shutdown code shown, display shows OK at shutdown code menu. Otis Elevator Company Vantage London (10th Floor) Great West Road Brentford TW8 9AG London, England 0800 181 363. problem goes away for 5 months, and Jan 16, 2020 · I don’t know but maybe its going down mechanically and causing the lift to fault out. Jan 16, 2020 · Otis 211 is popping up STLD fault whenever unit is powered back up after power is off. 1. I have an Otis 211. #38832 - 01/20/25 06:41 #21446 - 08/21/17 11:05 PM Re: Otis 211 giving FLRP fault [Re: Weupnow] Joined: Mar 2016 Posts: 225 lowoil Elevator guy lowoil Elevator guy Joined: Mar 2016. Частотник ошибки PDF. Leaflet Revisions Date Revised : Fault Contact Cover: 5 . O21A32Y1 Type of coil This number will ap-pear on Otis coils preceded by 222C (Example: 222CY1) No. 2 stop hydro. Fault code 0102 occurs when the door cannot close within the set time without proper door closing signals. by the Otis Service Center for the standard version of the product titled on the preceding page. have a 211, car intermittently gets a DLFB fault. otis 211 Posted By: Scott Davidson I have been t/s a 211, and noticed that the readout on the lcd screen, will usually tell what opmode it is in, what floor etc. REPLACEMENT FAULT CONTACT COVER . problem goes away for 5 months, and Jan 16, 2020 · Otis 211 MUSS fault James Dattilo: 02/05/24 05:55 PM: Re: Otis 211 MUSS fault Indirtwetrust: 02/06/24 12:52 AM: Re: Otis 211 MUSS fault EElevator: 02/06/24 01:58 AM: Re: Otis 211 MUSS fault James Dattilo: 02/06/24 10:11 PM: Re: Otis 211 MUSS fault Indirtwetrust: 02/07/24 01:22 AM: Re: Otis 211 MUSS fault James Dattilo: 02/07/24 02:02 AM: Re have a 211, car intermittently gets a DLFB fault. I was always constantly stressed when working for the internationals. I know this means that it is on fire service phase 1. As far as the low oil switch you need to not only turn on the switch in software but there is also a jumper on the board that needs to be removed. I took all the wires off the motor starter and overload to eliminate the starter being the cause. News Feed; Facebook; Instagram; Spare Parts Leaflet . 100% (1) Jan 13, 2016 · We have an Otis 211 that we are getting intermittent STLD faults. #22958 - 02/05/18 10:03 PM Re: Otis 211 [ Re: Johnny ] May 30, 2010 · Hey Mate, by the looks of that picture you have there an Otis 311 with the RCB and MCB boards on the right there. DC,DOL,RDC and RDOL relays are active. I have an Otis 211 hydraulic elevator that is currently in the pit with a readout of STLU on the display in the controller. I know the numbers are just counters and NAV is not avai I have an Otis 211 hydraulic elevator that is currently in the pit with a readout of STLU on the display in the controller. 22 : 5–22 . I have replaced selector card; and tape guides; checked all magnate placement and orientation at all 3 floors and slowdowns. Otis Brothers & Co. Ran car for an hour with no issues. Fault 17 (this fault was provided by -screwdriver friend) T-3100 elevator, the user reported that the elevator sometimes lost floors. of BREAKING contacts Jun 17, 2013 · I have an Otis 211 hydraulic elevator that is currently in the pit with a readout of STLU on the display in the controller. Any sugge Jun 17, 2013 · I have an Otis 211 hydraulic elevator that is currently in the pit with a readout of STLU on the display in the controller. made adjustments to the cam underneath the car to allow the switch not to randomly open up when it shouldn,t usually set 1. I have been told that I need to do a hard fault reset in the controller to get the elevator to move. No paperwork on job and no hand tool. Now when I either pull the wire or the building device puts the elevator on phase one I can not reset it at the key switch back to normal operation. The Otis solution is to provide the signal through an added timer and the Run Input. Every time when I arrive the smokes a Otis Signature Service™ With each of our service packages, we offer elevator repair and maintenance services with quick responses and transparent proactive communication. #10576 - 05/06/14 01:30 AM Re: Otis 211 control FLT readout [Re Oct 25, 2017 · Hey guys,Got an Otis 211 hydro that is displaying DTC on the board in the controller. Always being rushed to do more units in service, less time to do it (we actually had a 5 minute "basic" service at KONE, LOL), cover calls faster which meant speeding in the fraud and taking unsafe shortcuts. The modernization plan you’ll receive will be customized to your building needs and budget. Page 9 1900s, a time when “big business” flourished. Found the car shut down at the second landing with the PI flashing the proper floor. Jan 16, 2020 · Hey there, I’ve got an Otis 211 that every time there is a power outage in the area, the elevator will fault out with a 2EFO fault and the car will park at the second landing with the doors open. Every time when I arrive the smokes a Jan 13, 2016 · We have an Otis 211 that we are getting intermittent STLD faults. , and they will also do everything they can with their lawyers to make sure that nobody builds a service tool, when they know that it uses a standard configuration and protocol that they do not own. Unpublished Work —© Otis Elevator Co. problem goes away for 5 months, and We would like to show you a description here but the site won’t allow us. thanks ps, the fault happens once every couple of weeks for the last few months. Industry-leading service that only Otis can provide. so instead of AUD, D, DLF, DOL, DSR1, DSR2, EES, Unpublished Work—Otis Elevator Co. Jan 13, 2014 · #9515 - 01/13/14 02:14 PM Re: otis 211 dlfb fault Joined: Jan 2014 Posts: 2 TommyT stranger TommyT stranger Joined: Jan 2014 Posts: 2 Las Vegas, Nevada, USA : I'VE Aug 21, 2017 · Hello I have an Otis 211 I'm working on that keeps giving a FLRP fault and shutting the unit down 6/7 times, once reset it goes right back to working, anyone familiar? (FLRP = invalid floor position) #21446 - 08/21/17 11:05 PM Re: Otis 211 giving FLRP fault [ Re: Weupnow ] Jun 17, 2013 · I have an Otis 211 hydraulic elevator that is currently in the pit with a readout of STLU on the display in the controller. Turned out that the magnets were curling off the tape and causing the issue. But the car will eventually relevel up 3 or 4 times f User Manual Release Date; GAA817A Installation Manual Field Installation Manual FIM for CSA: 2020-01-10: GAA817A Manual GAA25QZ_FIM_NAAx: 2020-01-10 Jan 18, 2012 · I have been t/s a 211, and noticed that the readout on the lcd screen, will usually tell what opmode it is in, what floor etc. Customer cycles power to restore operation . Cleared ram of the fault. Our complete replacement switches (O2100 series) for the Otis Type A6164BP Magnet Switch are shipped with a coil. Otis Elevator successfully installed elevators, giving the company a chance to display its product at the fair’s centerpiece attraction. still the problem continued. Has anyone else encountered that?. The parts are chosen by Otis associates from: Engineering, Field Engineering, Service Engineering, and Manufacturing. 2. Sep 22, 2011 · 4. problem goes away for 5 months, and May 24, 2019 · Otis 211 - 05/24/19 02:20 AM Having an issue with an Otis 211 with a dccp fault with no prints or logs on site was wondering if anyone had any info on the fault. The HydroFit elevator saves time and money on your jobsite by being machine room-less. problem goes away for 5 months, and Otis 211 is popping up STLD fault whenever unit is powered back up after power is off. I can not figure this one out. Magnet Switches for Otis Type A6164BP Adams tests every single switch/relay. The LRUs are chosen by a team of Otis FAULT CONTACTOR . Otis optimizes equipment performance throughout each product’s lifecycle. . It’s carefully designed to help coordinate busy trades by locating hall call buttons in the door jamb. 5. When I put the elevator into fire service phase one I can turn it to bypass and reset elevator back to normal operation at the key switch . Safety circ Jan 16, 2020 · #36795 - 02/06/24 12:52 AM Re: Otis 211 MUSS fault [Re: James Dattilo] Joined: Dec 2015 Posts: 1,654 Indirtwetrust ElevatorPractitioner Indirtwetrust ElevatorPractitioner Joined: Dec 2015 Posts: 1,654 Local 18 as far as the scrolling message i think it does that when it gets noise on the line nothing to worry about. Fuses are good. we replaced the cartop board, changed bottom limit switch, checked all valve wiring. 15 - - - 22 . Oct 1, 2011 · On that last post, if you add oil additive for a tight packing it will change the viscosity of the oil. ; 2022 September 21, 2022 Page 15 A**21380AAC Card Cage 10-AAA21380AAA Subassembly Otis 211 (possibly also called Otis Elevonic 211, unless that is a different model) is an Otis hydraulic elevator controller. • Check that the brakes are picking • Check for incorrect motor and encoder phase rotation • Check for incorrect motor parameter setting in the A5 MOTOR Sep 24, 2017 · Working on an Otis 211 which keeps giving me FLRP code (invalid floor position code) I've changed guides, even changed selector board, checked magnets, unit will work properly for 2,or 3 days and then shut down with FLRP fault, all needed to get it back up and running is a reset. If they are good check the I/O board wiring. I know there’s a solution for it using a timer but can seem to find the wiring or write up on it anywhere. Add more hydraulic fluid as needed. Inspect the plunger and plunger guides that make up the Otis 211's hydraulic system. 6. Our mechanics are not only highly trained and equipped with proprietary apps to provide you with our highest level of safety and service – they’re also committed to Otis Elevator Company Bloomfield, Connecticut USA 211 hydraulic controller. It may run for a month and then I will have this fault a couple times over a week and then go away for Dec 1, 2017 · I'm getting a dccs fault on an otis 211. Operating Current (AMPS) Overload Range (AMPS) Existing Starter P/N New Starter P/N Replacement Fault 0 B25:Missing step/pallet upper landing OTIS B25 1 B26:Missing step/pallet lower landing OTIS B26 2 S5 :Floor plate upper landing OTIS S5 3 S6 :Floor plate lower landing OTIS S6 4 XXX:Fault Finder wiring/setup failure OTISXXXX 5 S32:Second brake line wear contact OTIS S32 6 B2 :Motor thermic device OTIS B2 7 ARS:Light curtain occupied OTIS ARS The document provides fault codes for an OTIS elevator. HP at 200-208 V HP at 220-240 V HP at 440-480 V Max. I can not get the dtc to go away and the car will not run on normal or inspect. Mar 7, 2019 · Everything seems good. problem goes away for 5 months, and Oct 9, 2013 · have a 211, car intermittently gets a DLFB fault. Slowdown and limit switches ohm out fine. Replacement Otis switch, model no. Kiwi, it's a job. L4s bottom directional is opening while sitting at the bottom landing. United States (EN) Otis World Headquarters 1 Carrier Place Farmington, CT 06032, USA (800) 233-6847. I believe that driver is off that line I dont have the prints in front of me. Job is over 100 miles out. it was about once a month for 3-4 months. Jan 18, 2012 · I have been t/s a 211, and noticed that the readout on the lcd screen, will usually tell what opmode it is in, what floor etc. When I sit on car top the tape readers door Zone LEDs stay lit and the Lu and ld lights never light up. Door bypass is reading properly from meter. Jan 16, 2020 · Hello all, have a otis 211 hydro 3 stop and intermittently shutting down on "stlu". Yes Otis directs some of their guys to this place so I guess they aren't really against it. But more for people selling their service tools and manuals. Mar 21, 2013 · Have a newer Otis 211 5 stop with 1 short floor. 10-AAA21241A. Save construction time and cost. It has front and rear doors that are both closed. We attempt to make part identification as easy as possible. Low voltage is normally attributable to a fuse problem. problem goes away for 5 months, and Mar 24, 2019 · Otis 211 ; 3 stop telescopic hydro; 3 inline openings ; no rear Problem: unit has just started getting stuck ; FLRP fault. Feb 8, 2017 · I am getting this fault and then after a reset it is good for a day or so then it comes back in. , 2022 10-AAA21241K Soft Starter Assemblies AAA21240AD1–AD10 NOTE 1: Building power supply 200–240 V for use with 6 or 12 lead Wye-Delta wound motors only. Even though the safeties and door circuits appear fine it will not run up on inspection. We glued the magnets and the problem went away for several weeks then happened again once. Replaced the lithium battery on the main board. 3. Magnets are glued down to proper positions. Never attempts to make a run before it pops up. merged in 1898 with several U. We have looked at some of the obvious things such as slowdowns, interlocks, valve(new)and selector. April 27, 2004 / Page 1 of 15 Supersedes SPL 10- AAA21241A Dated September 30, 2003 . My controller is reading a TCI fault on the screen and will not reset. I have no plans or manuals on this controller. 5–22 . Jan 16, 2020 · I have an Otis 211 with a Muss fault. elevator companies in Boston, Chicago, and Philadelphia to become the Otis Elevator Company. We have an Otis 211 that we are getting intermittent STLD faults. As to your "stlu" fault check your upper limit switches there always on the edge, I think its The L4s sw. 5 pages. I would check L3S contacts. So yes they probably watch. Check the blain valve pressure meter. OTIS Elevator Fault Code: LCB-2, TCBC and GECB Board Faults - Elevatorvip - Com - 1627641777743. PDF. Our service teams have the best training in the industry, experience on every type of elevator or escalator and have the knowledge and technology tools that can Sep 24, 2017 · Working on an Otis 211 which keeps giving me FLRP code (invalid floor position code) I've changed guides, even changed selector board, checked magnets, unit will work properly for 2,or 3 days and then shut down with FLRP fault, all needed to get it back up and running is a reset. 1 . Any help would be greatly appreciated. Jul 1, 2013 · Agreed. The SPL, however, cannot be all inclusive. It was first made in 1987. Give them away and what can they do? lol Just don't sign anything ever. Ask what the fault codes is and it's description. But now that i think about it you p Sep 26, 2017 · Working on an Otis 211 which keeps giving me FLRP code (invalid floor position code) I've changed guides, even changed selector board, checked magnets, unit will work properly for 2,or 3 days and then shut down with FLRP fault, all needed to get it back up and running is a reset. Hidden. Oct 9, 2013 · have a 211, car intermittently gets a DLFB fault. Next morning same fault. STM power fail is just a generic fault telling us that the lift has lost power for some reason and as a result has shutdown. Does it no matter where the car is in the hoistway. problem goes away for 5 months, and Mar 21, 2013 · Have a newer Otis 211 5 stop with 1 short floor. clearing most of codes. They directed me here years ago. Unpublished Work—Otis Elevator Co. A common misconception is that 211 is a model name which is false; it only applies to the Jun 17, 2013 · I have an Otis 211 hydraulic elevator that is currently in the pit with a readout of STLU on the display in the controller. ; 2004 The MUSS fault is is a well documented symptom resulting from a failure in the soft starter. At least once a day, it shuts down. Is there something I’m missing here? Is there a certain way to reset a fault on an Otis 211? system is from Otis, you can rest assured that it comes with the reliability and service you’ve come to expect. Fault code 0101 means the elevator cannot operate in emergency power mode. Once we get to the site and reset it it will run for a couple of days or week then get another STLD fault. finally replaced the main cpu/io board. Ah Yes Down Leveling Feedback Pilot Fault. Feb 27, 2025 · I have an Otis 211 that was having intermittent FLRP issues and shutting down. 5 . Check the motor fuses and remove and replace any blown or otherwise malfunctioning fuses. found that fuse F7 was blown but installed new fuse but can't reset elevator. the mechanic has replaced the switch in the hatch, he says he has checked everything in the circuit, any ideas as to what may be happening. This controller was discontinued in 2013. problem goes away for 5 months, and May 5, 2014 · FLT is a description that there is a fault. have a 211, car intermittently gets a DLFB fault. If you scroll further through the fault log you will find other faults that should tell you why. AAA21240AD5 . problem goes away for 5 months, and Apr 19, 2013 · DLFB. I can get one Oct 14, 2014 · My controller is reading a TCI fault on the screen and will not reset. Fault code 0100 indicates a driver failure that prevents the elevator from operating. Tried a hard reset just goes right back to dccp. If bypassed is not set correctly you will get a "valv" fault, the car will creep up through viscosity mode. I know the numbers are just counters and NAV is not available. 5 . problem goes away for 5 months, and have a 211, car intermittently gets a DLFB fault. According to my fault sheet a door lock that is bouncing can cause the same thing. had this recently. Any suggestions Oct 7, 2024 · No power on doors DTC Fault think doors need reset have blue tool but can't connect initially connects but then goes to all Z's car runs on inspect but the when goes back to normal still no power on doors DTC comes up and nudging buzzer,can't reset from controller think it has to be top of Jun 17, 2013 · I have an Otis 211 hydraulic elevator that is currently in the pit with a readout of STLU on the display in the controller. Safety circ Jul 1, 2013 · Otis's intranet is the place that I was told about this site. AAA21240AD39 Otis is a company known for commitment to Safety, Quality and Ethics- our three absolutes. 7. Innovative technologies let Otis engineers precisely identify or anticipate possible issues. #12320 - 10/14/14 03:03 PM Re: Otis 211 controller fault. Any ideas? #19554 - 02/12/17 04:03 AM Re: OTIS 211 BYOP FAULT [ Re: micmerci ] Otis does everything they can to make sure that no information is available in terms of fault logs, setup, etc. Otis 211 Hydro [Re: Indirtwetrust] Joined: Feb 2018 Posts: 131 Jblack83 Fault Description Causes dEv Speed Dev Fault The deviation between the speed reference and speed feedback is greater than the setting in Spd Dev Flt Lvl (A1) and Spd Dev Flt Time (A1). LCB11 fault records are: 0100, 0201, 0231OVF210 fault records are: SHUT DOWN, 1LS INI DEC, LV MISSED and connected to 1LV, 2LV and then normal. Controller GEM, E311VF, MVS, HVS, and GMP (Mod) Spare Parts Leaflet 10-AAA21290R September 21, 2022/ Page 1 of 39 OBSOLESCENCE NOTICE The product covered in this SPL has been designated as obsolete and is no have a 211, car intermittently gets a DLFB fault. #10576 - 05/06/14 01:30 AM Re: Otis 211 control FLT readout [Re Mar 19, 2014 · #10144 - 03/19/14 08:02 PM Re: otis 211 dlfb fault [Re: Scott Davidson] Joined: Nov 2012 Posts: 27 matt 24 newbie matt 24 newbie Joined: Nov 2012 Posts: 27 OTIS Elevator, OTIS Elevator Accessories, Elevator Failure Code, Elevator Motherboard Failure Code, Elevator Motherboard Maintenance, Elevator Accessories Maintenance, LCB-2 Motherboard Failure, TCBC Motherboard Failure, GECB Motherboard Failure, Driver Failure, Inverter Failure, OTIS Elevator Motherboard Failure Oct 9, 2013 · have a 211, car intermittently gets a DLFB fault. sdmj tquiq lgxyog dpom bcozm qygskhy qlmrkn dgqb hjh fiif cuslhd jlfcp cfn pyld ben